Probes for ophthalmic surgery of the Eye

Our OMS brand probes help the surgeon perform cutting, manipulating and probing tasks during ophthalmic procedures. 

Advertisements
WP Rocket - WordPress Caching Plugin

Our range of probes includes:

  • Repositor.
  • PHACO Chopper.
  • Universal Chopper. 
  • Nagahara Chopper.
  • Fine Chopper.
  • Endothelium Chopper.
  • Blunt Chopper.
  • Iris Retractor.
  • Chalazion Curette.
  • Ball Type Chopper.
  • Vertical Chopper.
  • Sinskey Hook.
  • Reverse Sinskey Hook.
  • Nucleus Rotator.
  • No Hole Manipulator.
  • Lester Hook.
  • Handled Wire Vectis.
  • Handled Wire Vectis (Serated).
  • PHACO Spatula Y-Rotator.
  • PHACO Spatula Sharp/Blunt.
  • Rosenwassen Shovel.
  • Lacrimal Dilator.
  • Optic Zone Marker.

Repositor: Repositor is used for moving and repositioning the iris on pupillary margin. It is available in stainless steel and titanium variants. 

PHACO Chopper: PHACO chopper is used to split the nucleus in the capsular bag during the cataract surgery. It is available in stainless steel and titanium variants. 

Universal Chopper: Universal chopper is used to chop the nucleus and can also be used to manipulate the IOL for proper positioning in the eye. It can also be used to push or pull the iris in eyes with small pupil. It is available in stainless steel and titanium variants.  

Nagahara Chopper: Nagahara chopper is used in horizontal chopping of the nucleus in the capsular bag. It is available in stainless steel and titanium variants. 

Fine Chopper: Fine chopper is used to split the nucleus in the capsular bag during the cataract surgery. It is available in stainless steel and titanium variants. 

Endothelium Chopper: Endothelium chopper is used to protect corneal endothelium cells during PHACO emulsification of a hard cataract. It is available in stainless steel and titanium variants.

Blunt Chopper: Blunt chopper is used to manipulate the nucleus. It is available in stainless steel and titanium variants.

Iris Retractor: Iris retractor assists the surgeon in cataract surgery for a patient who has contracted pupil or intra-operative floppy iris syndrome. It is available in stainless steel and titanium variants.

Chalazion Curette: Chalazion curette is used for removing chalazion. Following the incision curette is used to scoop the cyst. It is available in stainless steel and titanium variants.

Ball Type Chopper: Ball type chopper is used to manipulate the nucleus. It is available in stainless steel and titanium variants.

Vertical Chopper: Vertical chopper is used to chop the nucleus vertically during PHACO emulsification while the PHACO probe is holding the nucleus in its place. It is available in stainless steel and titanium variants.

Sinskey Hook: Sinskey hook is used to maneuver lens tissues. It helps in extraction of the nucleus and can also be used to manipulate and position the intraocular lens in the eye. It is available in stainless steel and titanium variants.

Reverse Sinskey Hook: Reverse Sinskey hook is used to begin dissection in DSAEK surgery. It is available in stainless steel and titanium variants.

Nucleus Rotator: Nucleus rotator is used to rotate and manipulate the intraocular lens in the capsular bag. It is available in stainless steel and titanium variants.

No Hole Manipulator: No Hole manipulator is used to rotate and manipulate the intraocular lens in the capsular bag. It is available in stainless steel and titanium variants.

Lester Hook: Lester hook is used in handling and implanting intraocular lens during cataract surgery. It is available in stainless steel and titanium variants.

Handled Wire Vectis: Handled wire vectis assists the surgeon in removing the chopped pieces of the nucleus from the capsular bag. It is available in stainless steel and titanium variants.

Handled Wire Vectis (Serated) : Handled wire vectis (serated) assists the surgeon in removing the chopped pieces of the nucleus from the capsular bag. The vectis has serrations to offer better grip. It is available in stainless steel and titanium variants.

PHACO Spatula Y-Rotator: The Spatula is used during cataract surgery to hold the iris in place while manipulating the lens capsule and the nucleus. The Y-Rotator is used to rotate, manipulate and position the intraocular lens in the capsular bag. It is available in stainless steel and titanium variants.

PHACO Spatula Sharp/Blunt: The PHACO Spatula Blunt is used during the cataract surgery to hold the iris in place while manipulating the lens capsule and nucleus. The PHACO Spatula Sharp is also used to rotate the nucleus to the required position to extract it from the capsular bag. It is available in stainless steel and titanium variants.

Rosenwassen Shovel: Rosenwassen Shovel is used during DSAEK surgery to deposit the folded tissue in the anterior bag. It can also be used as a base for folding the tissues. It is available in stainless steel and titanium variants.

Lacrimal Dilator: Lacrimal dilator is used in Lacrimal system procedure to enlarge the puncta and canaliculus and also be used for probing, stenting and punctal plug placement. It is available in stainless steel and titanium variants.

Optic Zone Marker: Optic zone marker is used to mark certain zones of the corneal epithelium which serves as a guide for trephine during corneal transplant surgery. It is available in stainless steel and titanium variants.

OMS brand Probes Market: We cater to the Indian domestic market with a country wide delivery capability.